CEE ID: 3690Status:Available
Model: Omni 7
Vendor: Speedline DOM: 2/97 Condition: Condition superior to inline with its age
Facility Requirements 440V, 3ph, 82kVA, 60 hz
Approx. Dimmensions 194"x51"x56" @ 3960 lbs
Configuration: Water cooled (superior to air cooling, chillers available) Edge/Mesh Left to right Auto hood lift Chain Oilers
Specifications: - Heating chamber length: 98.0" (2489 mm) - dimension does not include the length of the cooling module - Panel heater dimensions: Length: 12.0" (305 mm) each Width: 24.0" (610 mm) each - Heater power rating: 8000W per panel heater @ 240/415/480V in zones 1 and 7 (top and bottom) 4320W per panel heater @ 240/415/480V in zones 2 - 6 (top and bottom) - Maximum heating capacity: 77.2 kW (263,600 BTU/hr) @ 240/415/480V - Heater control: Proportional-Integral-Derivative (PID) heater control; software adjustable - Thermocouples: K-type; grounded junction; stainless steel sheathed; stainless steel overbraid - Heater temperature range: 0- 280C (0- 536F) measuring forced convection gas temperature - High temperature protection: Standard machine controls have 3 levels of built-in thermal protection for the heating section: - Process temperature deviation alarms (factory set defaults, user selectable parameters) - High temperature limit alarm (factory set defaults, user selectable parameters) - Thermocouple failure detection (non-adjustable) - Temperature control accuracy: +/-1C (+/-2F) at no-load steady state. - Bare board maximum DT: Without Rail Heaters: +/-4C (+/-7F) Note: Typical is less than +/-2C (+/-4F) - Forced convection blowers: High volume forced convection; high temperature sealed bearing; built-in thermal overload protection; class F insulation; re-useable silicone gaskets; quick release electrical connections - Blower rating at 0 static pressure: 160 cfm (270 m3/hr), 50/60Hz, 230 VAC, 115 W, 0.50 amp
Total forced convection @ 60 Hz Top (9 blowers): 1440 cfm (3240 m3/hr) Bottom (7 blowers): 1120 cfm (2700 m3/hr) Total (16 blowers): 2560 cfm (5940 m3/hr) - Typical start-up time: Ambient to full process ready state: 15 min. (+/-5 min.) (Start-up time may be influenced
Description: STANDARD FEATURES: - Seven (7) heating zones (seven top and seven bottom forced convection heaters). - One piece cast aluminum panel heaters with embedded heating elements. - One (1) high volume forced convection blower in top and bottom zones 1 to 5. Zones 6 and 7 have two (2) forced convection blowers each on the top and one (1) forced convection blower each on the bottom. - Three (3) speed settings for blowers, providing approximately 100%, 75%, and 50% of convection flow. (Zone 1 blowers can be independently locked to low speed via software to reduce the total nitrogen consumption and oxygen ppm levels.) - Blower failure detection (including blower power failure) with feedback to computer and on-screen warning. - One (1) mechanical power lifts with ratchet clutch to provide computer controlled automated opening and closing of external hood and upper part of heating chamber tunnel, allowing full access to interior. - Multifunctional custom extrusion tunnel walls providing captive hardware mounting slots, integral nitrogen feed line, positive chamber sealing, and thermocouple wireways.
Terms of Sale: This unit is located in the CEE facility in the Chicago area. A CEE technician will demonstrate the unit fully functional for your live or video acceptance. If you require special acceptance criteria, please discuss this with your CEE sales agent. Availability is subject to prior sale.
Disclaimer
Information is provided for your convenience as our good faith estimate for this equipment. CEE does not warrant the accuracy of this information due to the nature of used equipment. Used equipment can be customized, altered, or simply worn beyond the capability to perform to original specifications. If certain details are critical for your application, we highly recommend testing the machines performance on that criteria. Please notify your CEE sales representative prior to purchase and we will propose solutions for your concerns. CEE's goal is always to minimize your risk.
The Capital Equipment Exchange Company
2802 Barney Court
McHenry, IL 60051
ph: 815.363.0800 / fx:815.363.0809