Glenbrook Technologies RTX-113 X-Ray Inspection

Glenbrook Technologies RTX-113 X-Ray Inspection {ID: 7557}

Status: Available
DOM: 11/2005
Condition: Superior to inline with its age
Quantity: 1

Request a Quote Go Back

Product installation requirements:

Facilities: 110V
Dimms: 42"H x 42"W x 24"D

Product Terms:

This unit is located in the CEE facility in the Chicago area. A CEE technician will demonstrate the unit fully functional either live or by video for your acceptance.  Availability is subject to prior sale.


Description

A high resolution system for real time imaging of multilayer and assembled boards including BGA components.  Includes high voltage 80 kv  x-ray tube, power supply and controls.  Features Glenbrook’s patented XRTV high sensitivity x-ray camera, enhanced with eight frame recursive averaging.  All contained in a safety shielded work station.  Image magnification of 15x.        

A unique X-ray inspection system, designed for rapid, reliable inspection of both multi-layer and assembled printed circuit boards.
 
The RTX-113 is designed for heavy production environments where X-ray is used to inspect PCBs and assembled PCBs containing advanced components such as BGAs, uBGAs and Flip Chips.The system is very versatile and features Glenbrook's patented, award-winning X-ray camera technology that generates high-resolution, high-sensitivity images, revealing defects as small as 0.001 inch with a full one inch diameter field of view. The RTX-113 provides affordable real-time X-ray imaging, reliable operation and easy servicing.


Specifications

Operating Voltage: 120v, 60hz or 220v, 50hz
Contrast Resolution: Can resolve .001 gold wire
Spatial Resolution: 20 lp/mm (with MicroTech™ option, up to 100 lp/mm)
Anode Voltage: 35-52kV
Anode Current: 20-50 microamps (internal adjustment)
Focal Spot to Image Plane Distance: 4-6 inches
X-ray Activation Mode: foot pedal or timer switch


Disclaimer

Information is provided for your convenience as our good faith estimate for this equipment. CEE does not warrant the accuracy of this information due to the nature of used equipment. Used equipment can be customized, altered, or simply worn beyond the capability to perform to original specifications. If certain details are critical for your application, we highly recommend testing the machines performance on that criteria. Please notify your CEE sales representative prior to purchase and we will propose solutions for your concerns. CEE's goal is always to minimize your risk.